2022 June
June was cold (the coldest hour was 2 °C and warmest hour was 19.7 °C). The split system was on (set to 23 °C during our typical winter solar generation period (10:00 am - 3:30pm), 21 °C overnight (9pm - 6am), and off during the peak periods) and the HRV was solidly in 'heating' season all month. School is back so the kids were at school, but on most days one parent was working from home. We were open for the International Passive House Open Days (June 25) and we had ~ 100 people through the house. Lots of people were very interested in Passive Houses as comfortable / affordable dwellings. We will likely be hosting visitors in November (11-13) as well. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the same axes for all months. Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined...