2023 November

Image
November's weather was more spring like (median temperature 19.3 °C). The HRV was mostly in the cooling season and we openned the windows a fair bit in the evening / night when it was cool out, and the split system was typically cooling during peak solar production. At the end of the month when we had significant rain the dehumidifier ran for a week or so during the day to help dry clothes. Outside temperatures ranged from 10 to 34 °C, while inside we were a comfortable 20.1 to 24.7 °C. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from...

2021 November (+ Spring)

Image
New normal version 2.0 for November: kids in School and the parents working from home ~4 days per week. The split system was off for the entire month and the HRV slid in and out of 'cooling season' and neutral modes of operation more times that I could keep track of. The HRV did a great job of keeping the house in the comfort zone (if I could set the cooling season trigger in half degree increments we would have bit in range a bit more). It was an abnormally wet and cool November. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've set the temperature range in hopes that they will be comparable across months. Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sen...

2021 August (+ Winter)

Image
Winter is done, but lockdown version 2.0 is not. In August the split system ran as a heater for most of the month from ~9:45am until 3:30pm, scheduled to take advantage of the solar production during that part of the day. On cooler nights we kept it on set to 19 °C. The HRV is working well and doing a great job of keeping the house in the comfort zone, although the gound floor is consistently a few degrees cooler than the top floor. During August we were all at home in our second significant COVID lockdown (and going a bit crazy). I am going to change to a more graphic heavy format. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hopes that they will be comparable across months. Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the ...

Fall...

 A new format, now that we have longer periods with comparable data... a work in progres... Percentage of hours in below, within, above the 20 - 25 °C target temperature range for the season (inside). Year % < 20 °C % 20 - 25 °C % > 25 °C 2020 5% 95% 0% 2021 5% 94% 1% Quantile inside temperatures (°C) for the season. Year Min 5% 25% Median 75% 95% Max 2020 19 20 21 22 23 24 25 2021 18 20 22 22 23 24 26 Quantile outside temperatures (°C) for the season. Year Min 5% 25% Median 75% 95% Max 2020 4 9 13 16 20 25 38 2021 4 8 13 17 19 24 34 Energy Use (kWh) for the season. Year Produced Consumed Export Import Net 2020 12.7 12.7 6.6 6.5 0.0 2021 12.6 11.1 7.2 5.7 1.4 Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist...