Posts

Showing posts from 2024

2024 September

Image
September alternated hot and cold(median temperature 17 °C). Outside temperatures ranged from 6 to 28 °C, while inside we were a comfortable 18 to 24 °C. The HRV was mostly between seasons abd the split system was off for the entire month. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every room of the house. Outside is the data from the wirelessTag sensors outside near the cubby house and HRV intake. The water wall and door data are not included. Energy production and consumption: 1. tota

2024 August

Image
August started cold and ended hot (median temperature 15 °C). Outside temperatures ranged from 3 to 30 °C, while inside we were a comfortable 18 to 24 °C. The HRV was in heating season for the first half of the month, but entered the cooling season the for the last couple days. The split system was set to heat during peak solar production during the first half of the month, and off for the second half. Spring flowers were out in full force by the end of the month! Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors sp

2024 July

Image
July was as cold as June (median temperature 11 °C) but not quite as gloomy (9kWh/day of solar production). Outside temperatures ranged from 2 to 22 °C, while inside we were a comfortable 18 to 24 °C. The HRV was in heating season the entire month, and the split system was set to heat during peak solar production (not that we had a whole lot of sun in June) and set to heat to 18 °C overnight for the entire month. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every room of the house. Outside

2024 June

Image
June was decidedly cold (median temperature 11 °C) and gloomy (8kWh/day of solar production is an all time low). Outside temperatures ranged from 2 to 22 °C, while inside we were a comfortable 18 to 23 °C. The HRV was in heating season nearly the entire month, and the split system was set to heat during peak solar production (not that we had a whole lot of sun in June) and set to heat to 18 °C overnight for essentially the entire month. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every ro

IPOD - June 2024

Image
International Passivehaus Open Days - June 2024 edition. We were open and hosted 40-50 people (didn't get an accurate count). We met some lovely people and chatted passive houses. Just because folks asked... a couple of graphs (using the same hourly data from the monthly summaries). An updated all available data (40,133 hours) histogram: An important note on these data. More than half of the hours above 25 °C (546/1026) occurred in the first 6 months of living in the house, and all of the hours where the inside temperature above 27 °C were in the first 6 months living in the house when we were still determining the optimal HRV settings and how to manage the house temperature (learning that a passive house is designed for temperature inertia and benefits from a set and forget approach). Looking at 37,258 hours between March 2020 - June 2024, the house is in the passive house target zone of 20 - 25 °C 95% of the time, and in our target range (18 - 12 °C) 99% of the time. The 18 °

2024 May

Image
May was decidedly wintery (median temperature 14 °C). Outside temperatures ranged from 5 to 24 °C, while inside we were a comfortable 19 to 24 °C. The HRV was in heating season nearly the entire month, and the split system was mostly set to heat during peak solar production (not that we had a whole lot of sun in May) for essentially the entire month. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every room of the house. Outside is the data from the wirelessTag sensors outside near the cubby

2024 April

Image
April moved into autumnal weather (median temperature 17 °C). Outside temperatures ranged from 9 to 31 °C, while inside we were a comfortable 19.9 to 24.9 °C. The split system was off for the entire month and the HRV was inbetween seasons. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every room of the house. Outside is the data from the wirelessTag sensors outside near the cubby house and HRV intake. The water wall and door data are not included. Energy production and consumption: 1. tota

Sustainable House Day - 2024

Image
Another successful Sustianable House Day. It was all quite civilised with 46 people across three sessions. Lots of great questions and interested people.

2024 March

Image
March had typical summer weather (hot days but cooling off at night)fading into fall towards the end of the month (median temperature 20.7 °C). The HRV was in the cooling season but we were able to cool the house by openning the windows in the evening / night (I runined what was set to be a perfect 100% in the passive hourse temperature range for the month by leaving the windows open on night). The split system was cooling during peak solar production but not overnight. Outside temperatures ranged from 12 to 24 °C, while inside we were a comfortable 19 to 25 °C. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R f

2024 February

Image
February was definitely summer but very overcast with much higher humidity and overnight temperatures than other months in recent memory (median temperature 21.7 °C). The HRV was in the cooling season and we were often not able to cool the house by openning the windows in the evening / night as the overnight temperature didn't drop far enough. The split system was cooling during peak solar production and even overnight when the temperature did not drop. Outside temperatures ranged from 14 to 38 °C, while inside we were a comfortable 20 to 25 °C. The month was quite overcast which decreased our solar production... and running the A/C overnight resulted in higher energy consumption relative to last year. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculat

2024 January

Image
January was definitely summer but very overcast with much higher humidity and overnight temperatures than other months in recent memory (median temperature 22.3 °C). The HRV was in the cooling season and we were often not able to cool the house by openning the windows in the evening / night as the overnight temperature didn't drop enough. The split system was cooling during peak solar production and even overnight when the temperature did not drop. Outside temperatures ranged from 15 to 38 °C, while inside we were a comfortable 21.6 to 25.9 °C. The month was quite overcast which decreased our solar production... and running the A/C overnight resulted in higher energy consumption relative to last year. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculate

2023 December

Image
Decembers's weather was definitely summer but not super hot (median temperature 21.4 °C). The HRV was in the cooling season and we openned the windows a fair bit in the evening / night when it was cool out, and the split system was typically cooling during peak solar production. Outside temperatures ranged from 14 to 42 °C, while inside we were a comfortable 19.7 to 25.1 °C. The last half of the month was quite overcast which decreased our solar production... and with six of us for the holidays energy consumption was up relative to last year when we were away for the last half of the month. Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hope that I will be able to use the temperature range for all months. Methods:  I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C ta