2021 June

Winter is here and we are definielty into the heating season now. In June the split system ran as a heater for most of the month from ~9:45am until 3:30pm, scheduled to take advantage of the solar production during that part of the day. The HRV is working well and doing a great job of keeping the house in the comfort zone, although the gound floor is consistently a few degrees cooler than the top floor. June started as "normal month" typically one adult is at work while the other is working from home, but we ended up all at home in our second significant COVID lockdown.



Percentage of hours in below, within, above the 20 - 25 °C target temperature range for the month.
Inside / Outside% < 20 °C% 20 - 25 °C% > 25 °C
inside19%81%0%
outside100%0%0%

Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from 12 wirelessTag sensors spread across every room of the house. Outside is the data from the wirelessTag sensors outside near the cubby house and HRV intake. The water wall and door data are not included.


Quantile temperatures (°C) for the month.
Inside / OutsideMin5%25%Median75%95%Max
inside18192021222425
outside35811131721

Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the indicated quantiles for each sensor (using the R functions 'aggregate' and 'quantile'). Inside includes data from 12 wirelessTag sensors spread across every room of the house. Outside is the data from the wirelessTag sensors in the cubby house, outside, and HRV intake. The water wall and door data are not included.

Monthly electricity data. We generated 306kWh, we used 411kWh, so we were net energy users for the month (3.5kWh/day). Because we don't have batteries, we exported 135.1kWh and imported 104.7kWh. We used a bit less enegy than last year (411kWh vs. 453kWh last year), but we made a lot less this year (306kWh vs. 374.4kWh).

Popular posts from this blog

Temperature (Out vs. Old vs. New)

international passive house open day...

Water wall...