2021 December

December and the new normal. The split system was on an automatic mode most of the month (cooling from 10:00 - 18:15) and the HRV was solidly in 'cooling season'. The HRV did a great job of keeping the house in the comfort zone. The kids were in school for the first half of the month and the parents are were in the office a few days a week, but we were mostly at home... again.

Temperature from inside and outside the house as the percentage of hours in 0.5 °C bins. I've scaled the temperature in hopes that they will be comparable across months.

Methods: I have taken the 5 minutely data from the wirelessTag sensors and calculated the median temperature for each hour and determined the proportion of hours falling inside of the 20 - 25 °C target temperature (using the R functions 'aggregate' and 'hist'). Inside includes data from the wirelessTag sensors spread across nearly every room of the house. Outside is the data from the wirelessTag sensors outside near the cubby house and HRV intake. The water wall and door data are not included.

Energy production and consumption: 1. total daily consumption daily energy production, 2. daily net energy production, and 3. energy independence (which is the percentage of our daily consumption that is met directly by our solar panels).

Methods: Data are taken from the Enphase Enlighten system. This reports solar generation and electricity consumption as well as import from and export to the grid in 15 minute intervals. The R function 'aggregate' is used to create daily values and the function 'vioplot' to create the plots. The plots show individual days as points, with the vertical black bar covering the middle 50% of the data, the big white circle is the middle of the data (median), the whiskers extend to the farthest points from the median that are not more than 1.5 times the interquartile range, and the grey 'violin' shows the distribution of the datapoints where the narrow portions indicates few datapoints and a wide portion indicates more commonly occurrence... much like a histogram.


Because why not:
the same plots as above but for calendar year 2021... Not bad 93% within the comfort range and generated an average of 1.3kWh per day more than we used. In stats they like to talk about the range of 95% of the data (in this case hours of the year). In 2021, 95% of the hours were between 19.6 °C and 25.1 °C. 99% of the data were between 18.8 °C and 25.8 °C. The hottest hour in the house was 26.6 °C, and the coldest was 17.7 °C. Those are average temperatures across all the indoor sensors.







Popular posts from this blog

Temperature (Out vs. Old vs. New)

international passive house open day...

Water wall...